Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Dent ; 143: 104877, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38316199

RESUMO

OBJECTIVE: This randomized controlled clinical trial evaluated the whitening efficacy, tooth sensitivity (TS), and volunteers' satisfaction following the use of activated charcoal powder and toothpaste. METHODS: Fifty-six volunteers were randomly allocated into 4 groups (n = 14) according to a 14-day toothbrushing or whitening treatment with activated charcoal powder (ACPW), activated charcoal toothpaste (ACT), regular fluoridated toothpaste (RT), and 10 % carbamide peroxide (CP). Objective (ΔE00) and subjective (ΔSGU) color and whiteness index (ΔWID) changes were calculated. Patients self-reported the risk and intensity of TS using a visual analogue scale and the volunteer's satisfaction was determined by a questionnaire. Color assessments were analyzed by Kruskal-Wallis followed by Dwas-Steel-Crithlow-Fligner, and absolute TS risk and volunteer's satisfaction by Fisher exact test (p < 0.05). RESULTS: ACPW and ACT promoted similar effects in ΔE00, ΔSGU, and ΔWID to that observed for RT. No significant difference was found in terms of TS risk intensity. TS risk became high after 7 and 14 days, with higher TS prevalence in CP. Volunteers reported that ACPW exhibited the lowest ease-of-use, comfort, and whitening satisfaction among groups (p < 0.05). CONCLUSION: Activated charcoal-based products presented a minor and unsatisfactory whitening effect while CP resulted in optimal tooth whitening and the highest level of satisfaction among volunteers. Risk was higher from 7 days onwards and was more pronounced in the CP. CLINICAL RELEVANCE: Based on the whitening effect and patient satisfaction, this controlled-randomized clinical evidence supports that the use of activated charcoal-based products should be discouraged.


Assuntos
Sensibilidade da Dentina , Clareamento Dental , Humanos , Peróxido de Hidrogênio/uso terapêutico , Carvão Vegetal/uso terapêutico , Cremes Dentais/uso terapêutico , Pós , Método Simples-Cego , Clareamento Dental/métodos , Peróxido de Carbamida , Sensibilidade da Dentina/tratamento farmacológico
2.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532506

RESUMO

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Assuntos
Clareamento Dental , Cremes Dentais , Microscopia Eletrônica de Varredura , Resinas Compostas , Peróxido de Hidrogênio
3.
Braz Oral Res ; 37: e092, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38055513

RESUMO

This study aimed to evaluate surface roughness (Sa), roughness profile (Rv), and enamel wear after brushing with different whitening toothpastes and charcoal powders. Sixty (n = 10) bovine enamel blocks (6 × 6 × 3 mm) were randomly distributed into six groups according to toothpaste type: regular toothpaste (CONT), toothpaste containing 2% hydrogen peroxide (HP), toothpaste containing titanium dioxide (TiO2), toothpaste containing charcoal (COAL), toothpaste containing charcoal and TiO2 (COAL+TiO2), and activated charcoal powder (COAL_PWD). Each block was subjected to 30,000 reciprocal cycles at a 1:3 proportion slurry. After brushing, the blocks were analyzed using an optical profilometer to determine Sa, Rv, and enamel wear. In addition, representative 3D images of each group and wear profiles were obtained. Sa was analyzed using generalized linear models followed by Bonferroni correction, whereas Rv was analyzed using one-way analysis of variance. After brushing, COAL and COAL+TiO2 showed higher Sa values than COAL_PWD. However, no significant difference was observed in Sa between whitening toothpaste and COAL_PWD, and CONT (p > 0.05). In addition, no differences were observed among the groups in Rv (p > 0.05). Conversely, enamel wear was higher for TiO2, COAL, COAL+TiO2, and COAL_PWD than for CONT. CONT showed the least enamel wear, whereas HP showed intermediate values. Representative 3D images and line profiles showed lower step-height and lower mean surface losses for the CONT and HP groups than for the other groups. Whitening toothpastes and COAL_PWD did not increase Sa or Rv compared with CONT, while CONT demonstrated lower enamel wear.


Assuntos
Carvão Vegetal , Cremes Dentais , Animais , Bovinos , Carvão Vegetal/farmacologia , Esmalte Dentário , Peróxido de Hidrogênio , Pós/farmacologia , Escovação Dentária
4.
J Mech Behav Biomed Mater ; 143: 105919, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37279637

RESUMO

This study developed an experimental flowable composite incorporated with niobium pentoxide (Nb2O5) combined or not with titanium dioxide co-doped with fluorine and nitrogen (NF_TiO2) and evaluated the mechanical and antibacterial properties. The experimental flowable composite (TEGDMA + BisGMA 1:1 + 60%wt - inorganic filler - borosilicate 0.7 µm) was formulated according to the type and concentration of Nb2O5 and NF_TiO2 (0.5, 1, 1.5 and 2 wt%) or NF_TiO2 + Nb2O5 (0.25, 0.5, 0.75 and 1 wt% - 1:1). The control groups were formed by the experimental composite without the incorporation of Nb2O5 and/or NF_TiO2 (GC-E) and by a commercial flowable composite (GC). The characterization of the surface of the composite and its particles was carried out using scanning electron microscopy (SEM) and energy dispersive x-rays (EDX). Specimens were manufactured and subjected to mechanical tests of flexural strength (FS) (n = 12), flexural modulus (FM) (n = 12), roughness (Ra) (n = 10), microhardness (n = 10), and contact angle (n = 10); and, to evaluate the antibacterial activity, they were submitted to tests of biofilm formation against S. mutans (CFU/mL) (n = 5), biofilm biomass by dry weight (n = 5) and confocal laser microscopy (%LIVE/DEAD) (n = 5). Data were submitted to one-way ANOVA and Tukey's post-hoc and, those that were not homoscedastic, but with normality, were submitted to Welch's ANOVA and Games-Howell's post-hoc. Dunnet's test was used to compare the controls with the other experimental groups (α = 5). The Nb2O5 particles had an average size of 32.4 µm and the nanoparticles (NPs) of NF_TiO2, 10 nm. EDX analysis identified isolated peaks of N, F, Ti, and Nb confirming the presence of these particles in the resin matrix. The 1.5% NF_TiO2 group had a higher FS and FM than the controls (p < 0.05). GC showed higher microhardness between groups (p < 0.05). There was no difference between the experimental groups regarding contact angle and roughness (p > 0.05), except for GC, which had the highest Ra values and the lowest contact angle between groups (p < 0.05). Composites containing 0.5%, 1%, 1.5%, and 2% Nb2O5, 1%, 1.5%, and 2% NF_TiO2 and 2% Nb2O5 + NF_TiO2 showed lower biofilm formation (p < 0.05), lower total biofilm biomass (p < 0.05), and a higher percentage of dead cells (44%, 52%, 52%, 79%, 42% 43%, 62%, 65%, respectively) than GC and GC-E (5% and 1%, respectively). It is concluded that the incorporation of 1.5% NF_TiO2 promoted a greater FS and FM among the experimental composites and that the addition of Nb2O5 particles (0.5%, 1%, 1.5%, and 2%), NF_TiO2 (1%, 1.5% and 2%) and the combination Nb2O5 + NF_TiO2 (2%) showed significant antibacterial effects.


Assuntos
Nanopartículas , Nióbio , Teste de Materiais , Resinas Compostas , Antibacterianos/farmacologia , Propriedades de Superfície
5.
Clin Oral Investig ; 27(8): 4827-4841, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37369816

RESUMO

OBJECTIVES: The objective of the study is to evaluate the bleaching potential of 6% hydrogen peroxide (6% HP) gels containing NF_TiO2 or Nb2O5 irradiated with a violet LED light and the effects on enamel mineral content and surface morphology. METHODS: Particles were synthesized, and experimental gels were chemically analyzed by preliminary and accelerated stability tests, pH, and HP decomposition rate. Bovine enamel blocks were treated with 6% HP gels containing (n = 10): 5% NF_TiO2, 5% Nb2O5, 2.5% NF_TiO2 + 2.5% Nb2O5 or without particles (6% HP), irradiated or not with LED, and the control was treated with 35% HP. Color (∆E00) and whitening index (∆WID) variations, surface microhardness (SH), average roughness (∆Ra), Ca-P concentration (EDS), and enamel morphology (SEM) were assessed. Bleaching was performed in 3 sessions of 30 min and 7-day intervals. Data were submitted to two- (pH, decomposition rate, ∆E00, and ∆WID) or three-way ANOVA and Bonferroni (SH), Kruskal-Wallis (∆Ra), and Dunnet tests (α = 0.05). RESULTS: No changes in the gel's color, odor, or translucency were observed. The pH (6 to 6.5) remained stable over time, and light irradiation boosted the HP decomposition rate. NF_TiO2 and Nb2O5-containing gels displayed higher ∆E00 and ΔWID when light-irradiated (p < 0.05). Nb2O5 and Nb2O5 + NF_TiO2 decreased enamel SH (p < 0.05), but no SH changes were found among groups (p > 0.05). No differences among groups were noted in ∆Ra, Ca-P content, and enamel morphology after treatments (p > 0.05). CONCLUSION: Experimental light-irradiated 6% HP gels containing NF_TiO2 or Nb2O5 were chemically stable and exhibited bleaching potential comparable with 35% HP. CLINICAL RELEVANCE: Low-concentrated HP gels containing NF_TiO2 or Nb2O5 and light-irradiated stand as a possible alternative to in-office bleaching.


Assuntos
Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Clareadores Dentários/farmacologia , Peróxido de Hidrogênio/farmacologia , Ácido Hipocloroso , Géis
6.
Am J Dent ; 36(3): 136-142, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37364191

RESUMO

PURPOSE: To determine caries inhibition potential of conventional and bulk-fill bioactive composites around restorations. METHODS: Enamel and dentin blocks were prepared using a diamond saw under water irrigation, finished (SiC, 600- and 800-grit) and polished (SiC 1,200, final polish= 0.2 µm). Blocks were then selected through enamel surface microhardness, and enamel and dentin standard cavities were restored (n=10/group) with conventional bioactive composite (Beautifil II, BTF), bulk-fill bioactive composite (Activa BioACTIVE, ACT), glass-ionomer cement (Ionofil Plus, ION), conventional composite (GrandioSO, GSO), and bulk-fill composite (Admira Fusion X-TRA, ADM). Afterwards, the blocks were subjected to pH cycling: 4 hours in demineralization and 20 hours in remineralization solutions for 7 days, before being cut in the middle. One half was used to calculate the carious lesion area (ΔS) using values obtained by cross-sectional microhardness (CSMH) testing. The other half was submitted to polarized light microscopy (PLM) and scanning electron microscopy (SEM). The % of internal gap formation (GAP) of restorations' replicas were analyzed under SEM. Data were analyzed by ANOVA and Tukey test (α= 5%). RESULTS: In terms of CSMH, ION group exhibited the lowest ΔS values, with no significant difference to ADM. The composites BTF and ACT were similar to each other (P< 0.05) and to their negative controls (GSO and ADM), respectively. ION showed lower caries formation under PLM, whereas the GSO group presented a greater demineralized area. ION presented the highest % of internal GAP formation. Bioactive composites (BTF and ACT) were similar to their corresponding conventional ones (GSO and ADM) in terms of GAP formation. CLINICAL SIGNIFICANCE: The glass-ionomer cement was more effective in inhibiting the formation of caries lesions around restorations. Because of the glass-ionomer cement's limited application in high load-bearing areas, the conventional bioactive composite would be a promising clinical choice.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Suscetibilidade à Cárie Dentária , Cárie Dentária/prevenção & controle , Cimentos de Ionômeros de Vidro/farmacologia , Esmalte Dentário , Restauração Dentária Permanente/efeitos adversos , Teste de Materiais
7.
Photodiagnosis Photodyn Ther ; 42: 103568, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37059164

RESUMO

PURPOSE: This study evaluated enamel with early-stage erosion/abrasion following bleaching with 20% and 45% carbamide peroxide (CP) gels containing fluoride (F) and irradiated with violet LED (LED). METHODS: Enamel blocks were immersed in 1% citric acid (5 min) and artificial saliva (120 min) three times to produce early-stage enamel erosion. Simulated toothbrushing was performed only after the first saliva immersion, to provoke enamel abrasion. The erosive/abraded enamel samples were submitted to (n=10): LED/CP20, CP20, LED/CP20_F, CP20_F, LED/CP45, CP45, LED/CP45_F, CP45_F, LED, and control (without treatment). The pH of the gels was assessed, and color (ΔE00) and whiteness index (ΔWID) changes were calculated after cycling (T1), and 7 days from bleaching (T2). Enamel surface roughness average (Ra) and Knoop microhardness (kg/mm2, %SHR) were evaluated at baseline (T0) at T1 and T2. Scanning electron microscopy evaluated the enamel surface morphology at T2. RESULTS: The gels' pH was neutral and CP20 and CP45 exhibited no differences in ΔE00 and ΔWID (p>0.05) but LED increased these parameters for CP20_F and CP45. Erosion/abrasion significantly decreased mean kg/mm2, and the LED group was the only one not increasing microhardness after bleaching (p>0.05). None of the groups fully recovered the initial microhardness. All groups exhibited %SHR similar to the control (p>0.05) and the increase in Ra was detected only after erosion/abrasion. CP20_F groups exhibited a more preserved enamel morphology. CONCLUSION: Light irradiation combined with low-concentrated CP gel promoted a bleaching effect comparable to the high-concentrated CP. The bleaching protocols did not adversely impact the surface of early-stage eroded/abraded enamel.


Assuntos
Fotoquimioterapia , Clareamento Dental , Peróxido de Carbamida , Peróxidos , Fluoretos , Ureia , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Ácido Hipocloroso , Géis
8.
J Mech Behav Biomed Mater ; 138: 105606, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525873

RESUMO

OBJECTIVE: To evaluate the effects of simulated gastric acid erosion combined with mechanical toothbrushing abrasion on the mechanical properties, surface topography, and biofilm adhesion of different CAD/CAM materials. MATERIAL AND METHODS: Specimens of zirconia-reinforced lithium silicate glass-ceramic (ZLS), polymer-infiltrated ceramic network (PICN), feldspathic glass-ceramic (FE), and two nanoceramic resins (RK, RG), were submitted to the following challenges: erosion (E), abrasion (A), erosion combined with abrasion (E + A), or remained untreated (control - C). After challenges, flexural strength was evaluated, while microhardness (KHN) and surface roughness (Ra) were tested before and after treatments. The biofilm adhesion (Streptococcus mutans ATCC 700610, Streptococcus sanguinis ATCC 10556 e Candida albicans MYA 2876) was determined by the counting of colonies forming units per milliliters (UFC/mL) after erosive and abrasive challenges. RESULTS: FE showed the lowest flexural strengths, while ZLS and RG exhibited the highest, while PICN and RK, had intermediate values. PICN, ZLS, and FE showed lower microhardness after E and E + A challenges than polymer-based materials (RG and RK). FE surface roughness increased after E and E + A challenges and after A and E + A challenges for RK. Biofilm formation after erosive/abrasive challenges was higher on ZLS than FE, RK, and RG, but no different than PICN. RK and RG exhibited the lowest biofilm formation among the groups. Furthermore, E + A challenges held significant changes in the surface of the materials, which were more severe on the surface of glass ceramics and hybrid materials. CONCLUSION: Erosive challenges combined with abrasion negatively influenced the mechanical properties and surface topography of most CAD/CAM materials and increased the biofilm adhesion on ZLS. Besides, the severity of the damage is related to the type and composition of each material.


Assuntos
Ácido Gástrico , Escovação Dentária , Teste de Materiais , Desenho Assistido por Computador , Cerâmica , Polímeros , Propriedades de Superfície , Porcelana Dentária
9.
Braz. j. oral sci ; 22: e238082, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1393422

RESUMO

Aim: To determine if the artificial staining with black tea (BT) influences the enamel microhardness before in-office bleaching and if BT staining is necessary to evaluate the efficacy of bleaching with 35% hydrogen peroxide Methods: Enamel/dentin blocks were randomized into groups according to the staining protocol (n=5/group): (CO) control ­ maintained in artificial saliva solution (AS); (BT4) immersed in black tea solution for 4 h; (BT24) immersed in black tea solution for 24 h. After the staining protocols, all specimens were kept in AS for one week, followed by bleaching (three sessions of HP application for 40 min). Knoop surface microhardness (kgF/mm2) was determined at baseline (T0), after staining (T1), after 7 days of storage in AS (T2), and after bleaching (T3). The color (∆E00) and coordinate changes (∆L, ∆a, ∆b) were measured using a digital spectrophotometer at T0 and T3. Data were submitted to one-way (∆E00, ∆L, ∆a, ∆b) or two-way ANOVA repeated measures (kgF/mm2) and Tukey's test (a=5%). Results: The staining protocols (BT4 and BT24) promoted significantly lower microhardness (T1 and T2, p<0.05) than CO, whereas CO was the only group to maintain microhardness values over time. Bleaching promoted perceptible ∆E00 without a significant difference among the groups regardless of the staining protocol (p=0.122). CO and BT4 showed no differences in terms of ∆L and ∆a (p>0.05), but BT4 displayed a higher ∆b than CO. Conclusion:The artificial staining with BT negatively affected the enamel surface microhardness and was not essential to evaluate the efficacy of 35% hydrogen peroxide bleaching


Assuntos
Coloração e Rotulagem , Chá/efeitos adversos , Clareamento Dental , Cor , Esmalte Dentário , Clareadores , Testes de Dureza , Peróxido de Hidrogênio
10.
Braz. oral res. (Online) ; 37: e092, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520518

RESUMO

Abstract This study aimed to evaluate surface roughness (Sa), roughness profile (Rv), and enamel wear after brushing with different whitening toothpastes and charcoal powders. Sixty (n = 10) bovine enamel blocks (6 × 6 × 3 mm) were randomly distributed into six groups according to toothpaste type: regular toothpaste (CONT), toothpaste containing 2% hydrogen peroxide (HP), toothpaste containing titanium dioxide (TiO2), toothpaste containing charcoal (COAL), toothpaste containing charcoal and TiO2 (COAL+TiO2), and activated charcoal powder (COAL_PWD). Each block was subjected to 30,000 reciprocal cycles at a 1:3 proportion slurry. After brushing, the blocks were analyzed using an optical profilometer to determine Sa, Rv, and enamel wear. In addition, representative 3D images of each group and wear profiles were obtained. Sa was analyzed using generalized linear models followed by Bonferroni correction, whereas Rv was analyzed using one-way analysis of variance. After brushing, COAL and COAL+TiO2 showed higher Sa values than COAL_PWD. However, no significant difference was observed in Sa between whitening toothpaste and COAL_PWD, and CONT (p > 0.05). In addition, no differences were observed among the groups in Rv (p > 0.05). Conversely, enamel wear was higher for TiO2, COAL, COAL+TiO2, and COAL_PWD than for CONT. CONT showed the least enamel wear, whereas HP showed intermediate values. Representative 3D images and line profiles showed lower step-height and lower mean surface losses for the CONT and HP groups than for the other groups. Whitening toothpastes and COAL_PWD did not increase Sa or Rv compared with CONT, while CONT demonstrated lower enamel wear.

11.
Nanomaterials (Basel) ; 12(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36080033

RESUMO

The present study reports on the development and testing of novel bleaching agents containing co-doped metaloxide nanoparticles (NP; 0%, 5%, 10% v/w) and hydrogen peroxide (HP, 0%, 6%, 15%, and 35%). Bovine blocks (n = 200, A = 36 mm2) were obtained and randomly distributed into experimental groups (n = 10/group). NPs were incorporated into gels before bleaching (3 sessions, 7 days apart, 30 min/session, irradiated with violet light-LT). Color changes (ΔE00, ΔWID), mineral content (CO32−, PO43−), and topography were assessed (spectrophotometer, ATR-FTIR, and AFM) before and after bleaching procedures (14 days). Metabolic status and three-dimensional components of non-disrupted Streptococcus mutans biofilms were investigated using a multimode reader and confocal microscopy. The results indicate that ΔE00 and ΔWID significantly increased with NPs' concentrations and LT. The enamel's mineral ratio was adversely impacted by HP, but alterations were less pronounced when using NP-containing gels. The enamel's topography was not damaged by the bleaching protocols tested. The bioluminescence results show that bleaching protocols do not render latent antibacterial properties to enamel, and the confocal microscopy results demonstrate that the 3-dimensional distribution of the components was affected by the protocols. The proposed nanotechnology improved the bleaching efficacy of experimental materials independent of hydrogen peroxide or irradiation and did not adversely impact the enamel's surface properties or its chemical content.

12.
Clin Oral Investig ; 26(5): 3899-3910, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35006294

RESUMO

OBJECTIVES: This study characterized a violet LED light (V-LED; bright max whitening) tooth whitening device and evaluated its efficacy on stained enamel compared to hydrogen peroxide (HP). MATERIALS AND METHODS: Characterization of the V-LED beam profile was performed using a laser beam-profiler. The irradiance was measured throughout an exposure cycle at 0- and 8-mm distances using an integrating sphere and a spectral radiometer. Bovine enamel/dentin blocks stained with black tea (BT), cigarette smoke (CS), or without staining (CONT) were subjected to V-LED or 40% HP (n = 10/group). Color parameters (ΔL, Δa, Δb, and ΔE00) were measured using a digital spectrophotometer. Light transmission was estimated through 1-mm-thick bovine enamel slices (n = 5). ΔL, Δb, ΔE00, and irradiance were analyzed by two-way ANOVAs and Tukey's tests, Δa by Kruskal-Wallis and Mann-Whitney tests, and light transmission by t-test (α = 5%). RESULTS: Heterogeneous beam distribution was observed for the emitting V-LED chips. After 20 sequential exposures, irradiance levels were reduced 25-50%, regardless of the distance from V-LED. Localized irradiance values were statistically different between beam locations and different distances from the target. V-LED produced lower ΔE00, ΔL, Δa, and Δb values than HP for CONT and BT, with no differences for CS. Light transmittance decreased approximately 98% through 1-mm thick enamel. CONCLUSIONS: V-LED irradiance was heterogeneous and decreased throughout the exposure cycles and was also greatly reduced with increasing tip distance. V-LED produced a significantly lower whitening effect on BT and control teeth. CLINICAL RELEVANCE: This study contributes to the knowledge of V-LED and its clinical use.


Assuntos
Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Peróxido de Hidrogênio , Luz , Chá , Clareadores Dentários/farmacologia
13.
Nanomaterials (Basel) ; 13(1)2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36615911

RESUMO

Experimental adhesives containing co-doped metaloxide nanoparticles were demonstrated to display strong and long-term antibacterial properties against Streptococcus mutans biofilms. The present study represents an effort to characterize the shear-bond strength (SBS) and color stability (CS) of these novel biomaterials. Experimental adhesives were obtained by dispersing nitrogen and fluorine co-doped titanium dioxide nanoparticles (NF_TiO2, 10%, 20% or 30%, v/v%) into OptiBond Solo Plus (OPTB). Dentin surfaces were wet-polished (600-Grit). Specimens (n = 5/group) of Tetric EvoCeram were fabricated and bonded using either OPTB or experimental (OPTB + NF_TiO2) adhesives. Specimens were stored in water (37 °C) for twenty-four hours (T1), three months (T2), and six months (T3). At T1, T2, or T3, specimens were removed from water storage and were tested for SBS. Disc-shaped specimens (n = 10/group; d = 6.0 mm, t = 0.5 mm) of adhesives investigated were fabricated and subjected to thermocycling (10,000 cycles, 5−55 °C, 15 s dwell time). Specimens' colors were determined with a VITA Easyshade® V spectrophotometer (after every 1000 cycles). SBS data was analyzed using two-way ANOVA and post-hoc Tukey tests, while CS data was analyzed using one-way ANOVA and post-hoc Tukey tests (α = 0.05). Mean values of SBS ranged from 16.39 ± 4.20 MPa (OPTB + 30%NF_TiO2) to 19.11 ± 1.11 MPa (OPTB), from 12.99 ± 2.53 MPa (OPTB + 30% NF_TiO2) to 14.87 ± 2.02 (OPTB) and from 11.37 ± 1.89 (OPTB + 20% NF_TiO2) to 14.19 ± 2.24 (OPTB) after twenty-four hours, three months, and six months of water storage, respectively. Experimental materials had SBS values that were comparable (p > 0.05) to those from OPTB independently of nanoparticle concentration or time-point considered. Experimental materials with higher NF_TiO2 concentrations had less intense color variations and were more color stable than OPTB even after 10,000 thermocycles. In combination, the results reported have demonstrated that experimental adhesives can establish strong and durable bonds to human dentin while displaying colors that are more stable, thereby suggesting that the antibacterial nanotechnology investigated can withstand the harsh conditions within the oral cavity without compromising the esthetic component of dental restorations.

14.
Clin Oral Investig ; 26(3): 3141-3150, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34826031

RESUMO

OBJECTIVES: To evaluate the biaxial flexural strength (BFS), flexural modulus (BFM), and Knoop microhardness (KHN) of incremental and bulk-filled resin-based composites (RBCs) using extended curing exposure times. MATERIALS AND METHODS: Disc specimens (n = 8; 6-mm diameter) were fabricated using three stacked molds (0.5-mm thick for the top and bottom molds, and a 1-mm-thick center mold for the conventional and 3-mm thick for the bulk-fill RBCs). Conventional (Tetric EvoCeram/TCE and Filtek Z250/FIZ) and bulk-fill RBCs (Tetric EvoCeram Bulk Fill/TBF and Filtek One Bulk Fill Restorative/FOB) were evaluated. The stacked RBC-filled molds were light-cured for (1) the manufacturer-recommended exposure (MRE) duration; (2) 50%, and (3) 100% extension of the MRE. The BFS, BFM, and KHN of the top and bottom discs were measured. BFS and BFM were analyzed by three-way ANOVA (material*curing time*depth) and Tukey's post hoc (α = 0.05). KHN was analyzed by two-way ANOVA (curing time*depth) and Tukey's post hoc (α = 0.05). RESULTS: Extending the exposure duration did not change the BFS and BFM on the top of the RBCs, but the BFS and KHN increased at the bottom of bulk-fill RBCs. For the conventional RBCs, TCE showed the highest increase on BFS at the bottom, going from 53.6 MPa at T1 to 69.9 at T3. Among the bulk-fill RBCs, FOB presented the highest increase on the bottom BFS (T1: 101.0 ± 19.9 MPa, T3: 147.6 ± 12.9 MPa). For all RBCs and exposure times, BFS and KHN were lower at the bottom. Only FIZ and FOB reached a bottom-to-top hardness ratio of 80%, at T3 and T2. CONCLUSION: A significant increase on the BFS and KHN on the bottom of bulk-fill RBCs can be observed when the time of exposure to the curing light is double the MRE. However, extended exposure does not eliminate differences on the BFS and KHN between the shallow and deep regions of RBCs. TCE and TBF failed to reach an acceptable B/T hardness ratio at all evaluated exposure times. CLINICAL RELEVANCE: Mechanical properties of RBCs can be affected by insufficient polymerization, specially at deeper regions of the increment. Therefore, clinicians should consider applying twice the MRE to curing-light to polymerize the maximal increment thickness of bulk-fill RBCs.


Assuntos
Resinas Compostas , Materiais Dentários , Resistência à Flexão , Dureza , Teste de Materiais , Polimerização , Propriedades de Superfície
15.
Clin Oral Investig ; 26(1): 837-847, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34269885

RESUMO

OBJECTIVES: To evaluate the long-term outcomes of in-office bleaching with violet LED light (LED) alone or combined with carbamide (CP) or hydrogen (HP) peroxides. METHODS: Volunteers of a previous short-term study were recalled for 6- and 12-month follow-ups, according to the following interventions (n = 18/group): LED, CP, LED/CP, HP, and LED/HP. The objective color (ΔEab, ΔE00) and whiteness index (ΔWID) changes were calculated applying the CIELab coordinates' values obtained using a spectrophotometer. A visual shade guide determined the tooth's subjective color change (ΔSGU). Data were submitted to one-way ANOVA or Welch's ANOVA, following appropriate post hoc tests (α = 5%). RESULTS: The LED and CP groups exhibited the lowest ΔEab, ΔE00, and ΔSGU (p < 0.05), but the LED group displayed a significantly lower ΔWID. After 12 months, the LED/CP group presented a higher ΔEab and ΔE00 than the CP group (p < 0.05). ΔEab, ΔE00, ΔSGU, or ΔWID means did not differ statistically between the LED/CP and HP groups. The LED/HP group presented a higher ΔE00 than the HP group, regardless of the time. CONCLUSIONS: The bleaching efficacy of LED alone was significantly lower compared to the LED/CP and HP-containing protocols. After 12 months, the LED/CP and HP groups did not differ in bleaching efficacy. LED irradiation only increased the objective color change of bleaching gels. CLINICAL RELEVANCE: LED alone promoted a long-term perceptible bleaching, but not compatible with that of high-concentrated HP. The bleaching outcomes of violet irradiation to 37% CP were maintained over time, with LED/CP demonstrating comparable results to HP even after 12 months. NATIONAL CLINICAL TRIALS REGISTRY (REBEC): RBR-5t6bd9.


Assuntos
Clareadores Dentários , Clareamento Dental , Colorimetria , Seguimentos , Humanos , Peróxido de Hidrogênio , Peróxidos , Ureia
16.
J Esthet Restor Dent ; 34(3): 490-502, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34623017

RESUMO

OBJECTIVE: To answer the question: "Does the peroxide gel application regimen (single application vs. renewal) influence the efficacy and the tooth sensitivity outcomes of in-office tooth bleaching?" METHODS: The search was done in Pubmed, Cochrane, LILACS, Scopus, Web of Science, and EMBASE in February 2021 (updated in July 2021). Randomized clinical trials (RCT) comparing the single application vs. the renewal protocols of HP were included. The meta-analyses were performed for the objective (ΔEab ), subjective (ΔSGU) color changes, and absolute risk of tooth sensitivity (TS). Heterogeneity was evaluated using Q test (I2 ). Cochrane Collaboration tool assessed the risk of bias (RoB). The GRADE evaluated the certainty of evidence. RESULTS: Five RCT studies remained. Two studies showed high RoB, and three presented some concerns. No significant differences were observed between the protocols in terms of the ΔEab , ΔSGU, and TS. ΔEab exhibited substantial heterogeneity (I2  = 87%), while ΔSGU (I2  = 60%) and the TS (I2  = 62%) presented a moderate one. The certainty of evidence was considered low or very low, depending on the variable response and the evaluation time. CONCLUSION: The application regimen (single vs. renewal of HP) did not impact color change or the absolute risk of TS. CLINICAL SIGNIFICANCE: The renewal of bleaching gel during the in-office appointment may not be necessary. However, there is at least a low certainty of evidence. Because of this, further randomized clinical trials with appropriate methodology on this topic are encouraged.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio , Peróxidos , Clareamento Dental/métodos , Resultado do Tratamento
17.
Braz. j. oral sci ; 20: e213859, jan.-dez. 2021. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1253923

RESUMO

Aim: This study evaluated the effect of a desensitizer agent (DES) during bleaching with 10% carbamide peroxide (CP) on enamel microshear bond strength (µSBS). Methods: Sixty bovine incisors were obtained and randomly distributed into groups (n=15): (C) Control: no desensitizing or bleaching, (DES) desensitizing gel application, (CP) bleaching with 10% CP and (CP/DES) bleaching with 10% CP combined with DES. Bleaching was performed for 6 h/day for 14 consecutive days. DES was applied for 8 h only on the 7th and 14th days of therapy. Specimens were stored in artificial saliva among the CP or DES applications and submitted to µSBS testing at three postrestoration times (n=5): 24 h, 7 days, and 14 days after bleaching using a universal testing machine. Failure modes were observed under a stereomicroscope. Data were analyzed by two-way ANOVA and Tukey's test (α=5%). Results: Immediately after bleaching (24 h), CP promoted lower µSBS than the C and DES groups (p<0.05) but with no differences from the CP/DES. µSBS increased in the DES, CP, and CP/DES groups (p<0.05) when bonding was performed for 7 or 14 days elapsed from bleaching. CP/DES exhibited the highest µSBS among the groups 14 days after bleaching (p<0.05). Cohesive failure in enamel was predominant in the CP groups, while adhesive failure was mostly observed for the other groups. Conclusion: The use of a desensitizer during at-home bleaching maintained the enamel immediate bond strength, and its application favored bonding when the restoration was delayed for 14 days


Assuntos
Animais , Bovinos , Clareamento Dental , Esmalte Dentário , Resistência ao Cisalhamento
18.
Eur J Oral Sci ; 129(2): e12773, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33724583

RESUMO

This review compiles the literature on the antioxidants used after tooth bleaching with either low or high-concentrated carbamide and hydrogen peroxide to recover the bond strength. Antioxidants used in bleached teeth are mainly natural and non-enzymatic, except for catalase. Commonly, antioxidants are applied to remove any reactive oxygen species (ROS) residues left from bleaching gels, which adversely affect adhesive procedures, such as restorations or orthodontic brackets bonding. Even though sodium ascorbate, the most thoroughly investigated antioxidant, showed the most efficient bond strength recovery at 10% concentration, its performance depends on the type of solution and the application time. Natural extracts, such as proanthocyanidins and green tea, showed satisfactory results in the reversal of bond strength at 5% and 10% concentrations, respectively. Sodium ascorbyl phosphate, α-tocopherol, and catalase exhibited promising results, but further research is required. The adhesive system type plays an important role in the outcome of enamel bond strength after the antioxidant application. The postponement of either restorations or orthodontic brackets cementation following bleaching procedures seems to be efficiently replaced by antioxidant application prior to bonding procedures. However, the efficacy of using an antioxidant to recover bond strength depends on its type and application time.


Assuntos
Colagem Dentária , Clareamento Dental , Antioxidantes , Cimentos Dentários , Peróxidos , Resistência ao Cisalhamento , Ureia
19.
Photodiagnosis Photodyn Ther ; 34: 102194, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33513440

RESUMO

OBJECTIVES: To evaluate the bleaching efficacy of a violet radiation (VR) combined or not with bleaching gels on the color and mineral content of stained teeth. MATERIAL AND METHODS: Enamel/dentin blocks were obtained and stained (n = 50) with coffee, red wine, tobacco smoke, or were left non-stained. The stained or not-stained blocks (n = 10) were distributed into five bleaching groups (n = 10): VR, CP (37 % carbamide peroxide), VR/CP, HP (35 % hydrogen peroxide), and VR/HP. Color (ΔE00, ΔL, Δa, and Δb) and whiteness index (ΔWID) changes were evaluated after staining and after bleaching using a spectrophotometer. Calcium (Ca), phosphorous (P), and Ca/P contents (in wt%) were measured after bleaching using energy-dispersive X-ray spectroscopy (EDS). Data was statistically analyzed (α = 0.05) using two-way ANOVA and Tukey tests (ΔE00, ΔWID, ΔL, Δb, wt%) or Kruskal-Wallis and Dunn tests (Δa). RESULTS: VR alone caused higher colorimetric changes on coffee, tobacco and red wine-stained groups compared to non-stained enamel (p < 0.05). VR/CP exhibited higher colorimetric changes compared to CP in coffee and non-stained groups. The VR/CP, HP and VR/HP groups exhibited no change differences (p > 0.05). No differences were observed for the wt% of Ca, P and Ca/P between the groups. CONCLUSIONS: The violet radiation was more effective in bleaching stained rather than non-stained teeth. VR combined with 37 % carbamide peroxide was as effective as the HP agent. Besides, no adverse effects could be observed in the enamel mineral content, regardless of the bleaching protocol tested, according to the EDS semi-quantitative analysis.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes
20.
RGO (Porto Alegre) ; 69: e20210036, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1346859

RESUMO

ABSTRACT Tooth bleaching is one of the most conservative aesthetic techniques. At-home and in-office bleaching may be performed, as well as the combination of both techniques. As this combination may be done in different manners, distinct orders of combinations were proposed in this report. A 24 years-old man, whose upper central incisor and canine shades were A2 and A3 respectively, was initially treated by chair-side with 40-min application of 40% hydrogen peroxide (HP) for two sessions. Afterwards, an two-week overnight at-home bleaching was performed with 10% carbamide peroxide (CP). The shade of upper central incisors changed to 1M1 and canine was B1. Conversely, a 30 years-old woman was firstly conducted with at-home bleaching (overnight 4-weeks 10% CP) and, subsequently, with a single appointment of in-office bleaching for 45 minutes (35% HP). The shade of her upper central incisor changed from A1 to 0.5M1 and the upper canine from A3 to B1. The VITA classical (A1-D4) shade guide and VITA Bleached guide 3D-MASTER were used to determine the tooth color during the treatments. In both bleaching treatments, patients reported no significant tooth sensitivity and the final outcomes met their expectation.


RESUMO O clareamento dental é uma das técnicas estéticas mais conservadoras no âmbito odontológico. Técnicas de clareamento caseira ou de consultório, ou a combinação de ambas, podem ser realizadas para alcançar o prognóstico desejado. Esta combinação das técnicas pode ser realizada por meio de diferentes abordagens, como apresentado neste relato de casos. Um paciente do gênero masculino, 24 anos de idade, cujos incisivo central superior e caninos apresentaram cor A2 e A3, respectivamente, foi inicialmente submetido à técnica de clareamento de consultório de duração por sessão de 40 mim com gel de peróxido de hidrogênio (PH) 40%, em duas sessões. Posteriormente, a técnica de clareamento caseira foi realizada durante duas semanas com gel de peróxido de carbamida (PC) a uma concentração de 10%.A cor final dos incisivos centrais superiores foi alterada para 1M1, enquanto a dos caninos para B1. Por outro lado, uma paciente do gênero feminino, 30 anos de idade, foi inicialmente submetida ao clareamento caseiro (durante a noite, por 4 semanas- PC 10%), e subsequentemente, com aplicação pontual de agente clareador (PH 35%) em consultório, em sessão de 45 min. A cor do incisivo central superior da paciente, mudou de A1 para 0,5M1 e do canino superior de A3 para B1. As escalas de cor VITA Classic (A1-D4), e VITA Bleachedguided 3D-MASTER foram utilizadas nesta série de casos para determinar a coloração dos dentes durante os tratamentos. Em ambos os tratamentos, os pacientes não reportaram sensibilidade dental significante, e suas expectativas finais foram atendidas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...